Search Products
loading...

Seismic Aluminum Flooring System - Surface Application (SFE/SFEw)

Part Number:
EJN-SFE/SFEw
Out of Stock
Learn More

The Surface Mount Architectural Expansion Joint System performs in seismic conditions and has a contemporary look above the flooring.

Features

  • Seismic Technology
  • Horizontal and Vertical Thermal Movement
  • Seismic Movement with Lateral Shear
  • ADA Compliant

Specifications

Model SFE/SFEw
Material 6061-T5 Aluminum, Meets ASTM B221
6061-T6 Aluminum, Meets ASTM B209
5052 H32 Aluminum, Meets ASTM B209
Finish Mill
Movement Thermal: Horizontal and Vertical
Seismic: Lateral Shear
Mounting Surface
Joint Size 2-12"
Length 10 Linear Feet
Application Interior
Load Pedestrian and Light Cart
Installation Floor
Options Moisture barrier, Fire barrier, Additional Materials, Sizes and Finishes available upon request
Warranty 1 year

Order Guide

Use the table below to guide specification of available options. The part numbers are indicated in BOLD ORANGE text.

PART NUMBER APPLICATION JOINT SIZE
at mean T°F
EXPOSED
SIGHT LINE
TOTAL
MOVEMENT
EJN-SFE-200 Floor to Floor 2" (51mm) 6.75" (171mm) 2" (51mm)
EJN-SFE-400 Floor to Floor 4" (102mm) 10.18" (258mm) 4" (102mm)
EJN-SFE-600 Floor to Floor 6" (152mm) 13.25" (337mm) 6" (152mm)
EJN-SFE-800 Floor to Floor 8" (203mm) 16.75" (425mm) 8" (203mm)
EJN-SFE-1000 Floor to Floor 10" (254mm) 20.75" (527mm) 10" (254mm)
EJN-SFE-1200 Floor to Floor 12" (305mm) 24.75" (629mm) 12" (305mm)
EJN-SFE-200w Floor to Wall 2" (51mm) 4.37" (111mm) 1" (25mm)
EJN-SFE-400w Floor to Wall 4" (102mm) 7.06" (180mm) 2" (51mm)
EJN-SFE-600w Floor to Wall 6" (152mm) 9.62" (244mm) 3" (76mm)
EJN-SFE-800w Floor to Wall 8" (203mm) 15.37" (391mm) 4" (102mm)
EJN-SFE-1000w Floor to Wall 10" (254mm) 15.37" (391mm) 5" (127mm)
EJN-SFE-1200w Floor to Wall 12" (305mm) 18.37" (467mm) 7" (152mm)

WARRANTY

NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.

Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at Nystrom's discretion. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.


For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.

Warranty Support

Videos

Coming soon.
Coming soon.
Description Model Shop Drawing CAD Revit/BIM Data Sheet 3-Part Specs LEED Installation Warranty
Floor to Floor EJN-SFE-200 pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Floor EJN-SFE-400 pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Floor EJN-SFE-600 pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Floor EJN-SFE-800 pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Floor EJN-SFE-1000 pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Floor EJN-SFE-1200 pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Wall EJN-SFE-200w pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Wall EJN-SFE-400w pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Wall EJN-SFE-600w pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Wall EJN-SFE-800w pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Wall EJN-SFE-1000w pdf DWG LINK PDF WORD PDF PDF PDF
Floor to Wall EJN-SFE-1200w pdf DWG LINK PDF WORD PDF PDF PDF