Search Products
loading...

Seismic Aluminum Heavy-Duty Flooring System (PTS/PTSw)

Part Number:
EJN-PTS/PTSw
Out of Stock
Learn More

Description

The Heavy-Duty Seismic System can accommodate larger openings with multidirectional movement requirements. An integral moisture barrier keeps the weather out.

Features

  • Vehicular Rated - Parking Deck
  • Horizontal and Vertical Thermal Movement
  • Seismic Movement
  • Flush, Blockout
  • Coordinating Corners
  • ADA Compliant

Specifications

Model PTS/PTSw
Material 6063-T5 and 6061-T6 Aluminum, Meets ASTM B209 and B221
Finish Mill
Movement Thermal: Horizontal and Vertical
Seismic
Mounting Blockout
Joint Size 2 inches to 12 inches
Length 10 Linear Feet
Application Exterior
Load Vehicular
Installation Floor or Deck
Options Fire barrier, Additional Materials available upon request
Warranty 1 year

Order Guide

Use the table below to guide specification of available options. The part numbers are indicated in BOLD ORANGE text.

PART NUMBER INSTALLATION JOINT SIZE
at mean T°F
SYSTEM
WIDTH
TOTAL
MOVEMENT
EJN-PTS-200 Surface Mt Parking 2" (51mm) 15.87" (403mm) 2" (51mm)
EJN-PTS-400 Floor to Floor 4" (102mm) 18.06" (459mm) 3.68" (93mm)
EJN-PTS-600 Floor to Floor 6" (152mm) 20.06" (510mm) 6" (152mm)
EJN-PTS-800 Floor to Floor 8" (203mm) 22.06" (560mm) 8" (203mm)
EJN-PTS-1000 Floor to Floor 10" (254mm) 24.06" (611mm) 10" (254mm)
EJN-PTS-1200 Floor to Floor 12" (305mm) 26.06" (662mm) 12" (305mm)
EJN-PTS-200w Floor to Wall/Corner 2" (51mm) 8.94" (227mm) 1" (25mm)
EJN-PTS-400w Floor to Wall/Corner 4" (102mm) 11.06" (280mm) 2" (51mm)
EJN-PTS-600w Floor to Wall/Corner 6" (152mm) 13.06" (331mm) 3" (76mm)
EJN-PTS-800w Floor to Wall/Corner 8" (203mm) 15.06" (382mm) 4" (102mm)
EJN-PTS-1000w Floor to Wall/Corner 10" (254mm) 17.06" (433mm) 5" (127mm)
EJN-PTS-1200w Floor to Wall/Corner 12" (305mm) 19.06" (483mm) 6" (152mm)

WARRANTY

NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.

Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at the discretion of Nystrom. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.


For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.

 

Warranty Support

Videos

Coming soon.
Coming soon.
Description Model Shop Drawing CAD Revit/BIM Data Sheet 3-Part Specs LEED Installation Warranty
Deck to Deck EJN-PTS-200 PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Deck EJN-PTS-400 PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Deck EJN-PTS-600 PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Deck EJN-PTS-800 PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Deck EJN-PTS-1000 PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Deck EJN-PTS-1200 PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Wall EJN-PTS-200w PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Wall EJN-PTS-400w PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Wall EJN-PTS-600w PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Wall EJN-PTS-800w PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Wall EJN-PTS-1000w PDF DWG LINK PDF WORD PDF PDF PDF
Deck to Wall EJN-PTS-1200w PDF DWG LINK PDF WORD PDF PDF PDF

Specifications

Application:
Exterior Floor, Open Air Structures (Stadiums), Parking Structures
Material Type:
Metal Covers
Movement Type:
Seismic, Thermal