Seismic Slide System

Part Number:
FLC/FLCw
Out of Stock
Learn More

Description

This metal floor cover is designed for interior applications where low maintenance or tamper-resistant applications are desirable. With a recessed side frame and sloped center plate, this model helps reduce visual line as compared to other metal floor covers.

Features

  • Durable - Heavy Traffic
  • Minimal Sight Line
  • Horizontal and Vertical Thermal Movement
  • Seismic Movement with Lateral Shear
  • Block Out Installation
  • Coordinating Corners
  • ADA Compliant
Sweets ProductTAG


Specifications

Model FLC/FLCw
Material 6063-T6 Aluminum
Finish Mill
Movement Thermal: Horizontal and Vertical
Seismic: Lateral Shear
Mounting Block Out
Joint Size 1 inch to 6 inches
Length 10 Linear Feet
Application Interior
Load Pedestrian and Light Cart
Installation Floor
Options Moisture Barrier, Fire Barrier
Warranty 1 year

Order Guide

Use the table below to guide specification of available options. The part numbers are indicated in BOLD ORANGE text.

MODEL INSTALLATION JOINT SIZE
at mean T°F
SYSTEM
WIDTH
TOTAL
MOVEMENT
FLC-100 Floor-to-Floor 1" (25mm) 9.69" (246mm) 1" (25mm)
FLC-100w Floor-to-Wall 1" (25mm) 7.31" (186mm) 2" (51mm)
FLC-200 Floor-to-Floor 2" (51mm) 9.69" (246mm) 2" (51mm)
FLC-200w Floor-to-Wall 2" (51mm) 7.31" (186mm) 2" (51mm)
FLC-400 Floor-to-Floor 4" (102mm) 9.69" (246mm) 4" (102mm)
FLC-400w Floor-to-Wall 4" (102mm) 7.31" (186mm) 4" (102mm)
FLC-600 Floor-to-Floor 6" (152mm) 13.63" (346mm) 6" (152mm)
FLC-600w Floor-to-Wall 6" (152mm) 11.25" (286mm) 6" (152mm)

WARRANTY

NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.

Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at Nystrom's discretion. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.


For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.

Warranty Support

Videos

Coming soon.
Coming soon.
Description Model Shop Drawing CAD Revit/BIM Data Sheet 3-Part Specs LEED Installation Warranty
Floor-to-Floor FLC ZIP DWG PDF WORD WORD PDF PDF
Corner FLCw ZIP DWG PDF WORD WORDPDF PDF

Specifications

Material:
6063-T6 Aluminum
Finish:
Mill
Length:
10 Linear Feet
Installation:
Floor
Mounting:
Block Out