Expansion Joint CoversSmoke VentsRoof HatchesAccess PanelsFloor DoorsSafety RailingsLouversFire Cabinets

Browse Products by Image

   Non-Rated, Flush
   NT: 1" Flange 
   NW: Drywall Flange 
   NP: Plaster Flange 
 
   Non-Rated, Flush, Security
   MT: 1" Flange, 12ga 
   MW: Drywall Flange, 12ga 
   MP: Plaster Flange, 12ga 
   HS: High Security, 10ga 
   TS: Top Security, 7ga 
 
   Fire-Rated, Insulated
   IT: 1" Flange 
   IW: Drywall Flange 
   IP: Plaster Flange 
 
   Fire-Rated, Insulated, Security
   ST: 1" Flange 
   SW: Drywall Flange 
   SP: Plaster Flange 
 
   Fire-Rated, Uninsulated
   UT: 1" Flange 
   UW: Drywall Flange 
   UP: Plaster Flange 
 
   Exterior Panels
   XT: 1¼" Flange 
 
   Recessed Panels
   RA: No Flange 
   RW: Drywall Flange 
   RP: Plaster Flange 
 
   Specialty Panels
   FRD: Oversized Fire Rated 
   FRU: Upward Opening, Fire Rated 
   DTK: Draft Stop 
   PL: Plastic 
   LW: Light Weight, Insulated 


DescriptionSizesOptionsTechnical SpecsCSI SpecsCAD Drawings

ST Series - Access Panels

LATCHING/LOCKING OPTIONS
These latches/locks are the third character in the part code: (Example: NTC1212)
· M - Mortise cylinder lock preparation. The mortise preparation provides a higher level of security than the 'L' style lock. The locks can be matched to the project hardware. Nystrom's doors accept a standard 1-1/8" mortise cylinder by most lock manufacturers (Best, Corbin, Russwin, Schlage, etc.).
· D - Detention lock preparation. The detention lock preparation will accommodate several brands of heavy-duty detention deadbolt locks. The most common use for this option is in maximum security applications.
MATERIAL OPTIONS
These options are added to the part code after the size: (Example: ITK2424B)
· B - Galvanized bonderized steel. This material is an economical choice for use where a corrosion resistant material is required.
· S - Stainless steel type #304. With #4 satin polish finish. Stainless steel material is typically used in areas that require the highest level of corrosion resistance. It is also used in areas where a polished stainless steel look is desired.
· C - Drip cap on frame. The drip cap is mounted on the upper horizontal frame, and directs running water away from the face of the door to assist with weather resistance. This option is not available on fire rated panels.
· G - Gasketing. Gasketing can be applied to the doorstops of the frame to provide weather resistance and reduce airflow between the door and frame. A UL listed smoke seal gasket is also available.
· M - Masonry anchors. Masonry anchors secure the panel when installed in masonry.
Looking for an upward swinging access door or a large double leaf fire rated access door? See FRU series for more information.

D:\Sites\LocalUser\nystrom\content\0324.htm
 
   © 2005 Nystrom